34 research outputs found

    INTEGRAL timing and localization performance

    Full text link
    In this letter we report on the accuracy of the attitude, misalignment, orbit and time correlation which are used to perform scientific analyses of the INTEGRAL data. The boresight attitude during science pointings has an accuracy of 3 arcsec. At the center of the field, the misalignments have been calibrated leading to a location accuracy of 4 to 40 arcsec for the different instruments. The spacecraft position is known within 10 meters. The relative timing between instruments could be reconstructed within 10 microsec and the absolute timing within 40 microsec.Comment: 5 pages, 2 figures, accepted for publication in A+A letters, INTEGRAL special issu

    Parametric Design for Reconfigurable Software-Defined Radio

    Full text link

    Planck 2013 results. I. Overview of products and scientific results

    Get PDF

    Planck early results I : The Planck mission

    Get PDF
    Peer reviewe

    Planck pre-launch status : The Planck mission

    Get PDF
    Peer reviewe

    Planck 2013 results. I. Overview of products and scientific results

    Get PDF
    Peer reviewe

    An investigation into the biofilm-associated bacterial contamination of dental chair units and dental unit output water supplies and its control

    No full text
    THESIS 7391Many modern medical devices, including dental chair units (DCUs), are potential reservoirs of infection as they can harbour biofilm-associated microorganisms. This study investigated several aspects of DCUs related to cross-infection, particularly microbial contamination of dental unit waterline (DUW) output water and DCU suction systems. The first part of this study evaluated the efficacy of the novel Planmeca Waterline Cleaning System, the first integrated disinfection system specifically designed for the disinfection of DUWs, with the two hydrogen peroxide-based disinfectants Sterilex Ultra and Sanosil at reducing bacterial contamination of DUW output water in the Dublin Dental Hospital to safe levels (< 200 cfu/ml). Ten DCUs were retrofitted with the novel system: Sterilex Ultra and Sanosil were used weekly to disinfect six and four of these DCUs, respectively, over a 20-week and eight-week period, respectively. Both disinfectants were equally effective at reducing the bacterial density of DUW output water to < 200 cfu/ml and maintaining this water quality for at least a week. Following cessation of once-weekly disinfection with either disinfectant, DUW output water quality deteriorated within three weeks. Electron and confocal microscopy of the internal lumens of DUWs demonstrated that the improved water quality correlated with biofilm removal. Sanosil was found to be more effective, as the use of Sterilex Ultra was associated with clogging of DUWs in some DCUs. Following completion of this study all DCUs in the Hospital were retrofitted with the system. Two years after the implementation of weekly disinfection with Sanosil throughout the Hospital, it was noted that bacterial densities rose to significant levels five days following disinfection, which correlated with a significant increase in the prevalence of catalase-positive organisms in the DUW output water, probably due to the consistent use of the hydrogen- peroxide based disinfectant Sanosil

    Number

    No full text
    corecore